Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON UMYM5-0800-0250.
Ideal for the thermal input devices of Temperature Controllers
UMYM5-0800-0250
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Unit type: CJ1 Basic I/O Units OMRON UMYM5-0800-0250.
name: B7A Interface Units.
Specifications: I/O points, 32 inputs/outputs;
External connection, Removable terminal block .
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications OMRON UMYM5-0800-0250.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss . UMYM5-0800-0250.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eeexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
UMYM5-0800-0250 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=UMYM5-0800-0250&select=5