Power supply voltage: DC.
Sensing method: Retro-reflective without MSR function.
Sensing distance: 7 m[100 mm](When using E39-R1).
Output configu ration: NPN.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models) OMRON V-10-2A4.
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2
V-10-2A45 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC) OMRON V-10-2A4.
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available. Name: Basic Unit(gradient temperature control)(See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2 OMRON V-10-2A4. ).
Control outputs 3 and 4: Transistor output: 2 points(sourcing) .
Auxiliary output: None.
Functions: Heater burnout alarm, 2 (See note 3.); Event inputs, None.
Communications functions: G3ZA connection port,
RS-485 From End Unit, Port A, RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models.).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise. Operrating modes:: Flicker OFF start V-10-2A4.
Supply voltage: 110 VAC (50/60 Hz), 220 VAC (50/60 Hz).
Independent ON- and OFF-time settings. Furthermore,
combinations of long ON- or OFF-time and,
short OFF- or ON-time settings are possible.
Wide time rangess ffrom 0 V-10-2A4. 05 s to 300 h.
Easy sequence checks through instantaneous,
outputs for a zero set value at any time range.
Approved by UL, CSA, CE and CCC.
V-10-2A4 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=V-10-2A4&select=5