High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC / wire type.
Polarity: none.
Shape: non shield, M18.
Detection range: 14mm.
Action mode: NO. Input type: Platinum-resistance thermometer or thermocouple OMRON LY2 AC48.
Supply voltage: 100 to 240 VAC.
Output: 1 relay contact output (SPDT).
Highly Visible LCD Display with 2-color (Red and Green) LEDs
LY2 AC48
Wide input range - select from two types of platinum-resistance,
thermometers and ten types of thermocouples.
Front-panel key operation for easy setting.
Average processing function suppresses flicker OMRON LY2 AC48.
Temperature input shift and temperature unit selection functions .
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate).
Finger protective cover (standard equipment) protects against,
electric shock.
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to conform to U.S. and Canadian requirements under,
the Component Recognition Program of UL OMRON LY2 AC48.
CE marking. The main body: terminal type, temperature input type .
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance funcction is incrreased,
Further performance improvement LY2 AC48.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV LY2 AC48.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
LY2 AC48 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=LY2 AC48&select=5