Size: 96 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: - OMRON MKS2XTIN-11 AC100.
Communication: -.
Event input: 6 points.
Remote SP input: there
MKS2XTIN-11 AC100
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications OMRON MKS2XTIN-11 AC100.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports .
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON MKS2XTIN-11 AC100.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Model : CVM1D-BC051.
5-slot.Safety outputs *1: Instantaneous, 2 (Semi conductors); OFF-delayed*2, 0.
Auxiliary outputs *3: 2 (Semi conductors).
Logical AND connection input: 1.
Logical AND connection output: 1.
Max. OFF delay time *4: --.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Electronic Detection Mechanism for.
Better Stability in Non-contact Door.
Switch Operation. Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance perfformance .
The connecction method can be selected from a screw terminal and a PUSH-IN fastening terminal MKS2XTIN-11 AC100.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsiion Village (sold separately) connected to the computer after,
No power connection can be set MKS2XTIN-11 AC100.
It can be easily set by CS-Thermo (sold separately).
MKS2XTIN-11 AC100 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MKS2XTIN-11 AC100&select=5