Classification: Output (single contact), SPDT.
Rated voltage: 12 VDC, 24 VDC.
Slim-styled I/O Relay Saves Space in Panel.
SPST-NO, SPST-NC, and SPDT contact forms available for,
output (SPST-NO only for input).
Ultra-slim housing measuring 29 (W) x 10 (D) x 32 (H) mm.
All Output Relays provide a long endurance (1,000,000,
operations at 5 A), while all Input Relays provide microswitching,
power (100 μA at 1 V)
MM3XKP AC110
Approved by UL and CSA standards. Model: Shielded, M8.
Sensing distance: 1.5 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NC.
Proximity Sensor with Resin Case,
with Superb Water Resistance OMRON MM3XKP AC110.
IP68 protection.
Mutual interference prevention with models with different,
frequencies is also available . Shape: L DIP shaped terminal.
Pole number: 10.
Pole pole number: 0.
Minimum packing unit: 90.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province OMRON MM3XKP AC110.
A press type plug (XG4E) capable of using the relay is provided .
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicaated from the start of operation MM3XKP AC110.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions MM3XKP AC110. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.