Appearance: insert type.
Control supply voltage: DC24V.
Action elements: overload detection.
Action characteristic: lock, instant action type.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection OMRON MM4PN DC200/220.
A variety of models, such as anti time limit characteristics, lock time, instantaneous action, etc
MM4PN DC200/220, are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation.
When the current is large, the input resistance of the CT or the relay part is not needed, and the use is simple OMRON MM4PN DC200/220.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple . Open circuit mode: current circuit breaker.
Appearance: ADR shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 10VA below (except for reactor part).
Action current adjustment range (zero phase converter primary current):
0 OMRON MM4PN DC200/220. 1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1A; closed circuit 110V 15A DC 1000 (L/R=0ms),
Open 110V 1A DC 1000 (L/R=25ms) .
The relay control output circuit breaker switch: power capacity, switching capacity, AC110V/10A C110V/10A; (COS =1).
Quality: about 1kg.
External: Mount Searl N1.5.
High voltage grounding relay type K2GA thin,
Miniaturization, and digital type precision mounting.
Strong anti interference ability,
Stable operation in the arc grounding fault.
Can carry out fine current adjustment, easy to coordinate.
Set alarm terminal.
The adjusting part of the action current is a rotary switch mode, which is convenient for adjustment. Item: Sensor Head - Controller Extension Fiber Cable,
(flexible cable) (Fiber Adapter ZW-XFC provided).
Cable length: 10m.
To achieve a compact Sensor Head and high-resolution measurements,
the ZW Series uses a white light confocal principle to detect objects.
This principle is described below. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer .4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output MM4PN DC200/220.
Through the infrared port can be carried out from the frronnt of the communication MM4PN DC200/220.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.