Appearance: M4.
Sensing distance: 2 mm.
Connecting method: Pre-wired Models (2 m).
Cable specifications: PVC (oil-resistant).
Operation mode: NO.
Wire color /pin arrangement: Brown: +V, Black: Output, Blue: 0 V.
Model: PNP output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5 OMRON NL1-C. 4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available
NL1-C
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation OMRON NL1-C.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only) .
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. Size: 48 x 96mm.
Type: thermocouple type.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: voltage output (for driving SSR).
Temperature controller with single alarm output OMRON NL1-C.
SV and PV can be displayed at the same time .
Multiple temperature range allows setting the optimum temperature range.
The protection function can prevent the error in operation. Model: C200HW-CORT21-V1.
C200HW C Communications CANopen Master / Slave Unit C200HWCORT21Appearance: Unshielded.
Sensing surface: Top.
Sensing distance: 1.6 mm.
Output configuration: PNP.
Model: Operation mode, NC.
Advanced Performance and Wide.
Range of Selections in a Super.
compact Size.
Only 5.5 × 5.5 mm with a built-in Amplifier.
Maximum sensing distance: 2.5 mm. Stable detection even with,
workpiece fluctuations.
Response frequency: 1 kHz.
Low current consumption. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
2-Wire Transmitter Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savinngs in cosst and space compared,
with previous systems NL1-C.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems NL1-C.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
NL1-C Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=NL1-C&select=5