Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: output (special terminal) OMRON .
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved
H7EC-N-300
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) OMRON .
High speed sampling period 60ms .
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay) OMRON .
Setting the program settings that can perform flexible contact output .
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Cable: PVC.
Cable core number (core): 4.
Cable lead direction: straight line type.
Cable length L:10m.
The province, province hours maintenance, use waterproof connector environment and strong tolerance of FA.
Conform to IP67. FA small special connector flame retardant 94V-0.
The connector wiring system, convenient equipment maintenance, reduce equipment downtime.
IEC61076-2-101 (IEC60947-5-2).
For LED products, can clearly confirm the status of the sensor action. Power supply: AC power supply.
Output method: Transistor output source type.
Inputs points: 12 points.
Outputs points: 8 points.Number of beams: 22.
Protective height: 440mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions .
Serries connection is possible only with the MSF4800A OMRON H7EC-N-300.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt CCurtain functions OMRON H7EC-N-300.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
H7EC-N-300 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=H7EC-N-300&select=5