Size: 96 × 96 mm.
Control type: Position-proportional control(1 loop).
Control mode: Single-loop position-proportional control(See note.).
Outputs(control/transfer): Relay output(1 open, 1 close).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, No.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity
K3NP-PB2C-FLK6
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight OMRON .
Multiloop control, cascade control, and proportional control are,
possible with a single Controller .
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) OMRON .
DeviceNet Communications.
Data setting and monitoring can be performed without special programming . Actuator: Adjustable roller lever.
Conduit openings: M20.
2NC (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Cable: PUR.
Cable core number (core): 4.
Cable outside diameter: 4.7mm.
Cable lead direction: straighht line type .
Cable lenggth L:5m OMRON K3NP-PB2C-FLK6.
The province, province hours maintenance, use waterproof connector environment and strong tolerance of FA.
Conform to IP67.
FA small special connector flame retardant 94V-0.
The connector wiring system, convenient eequuipment maintenance,
Reduce equipment downtime OMRON K3NP-PB2C-FLK6.
IEC61076-2-101 (IEC60947-5-2).
For LED products, can clearly confirm the status of the sensor action.
K3NP-PB2C-FLK6 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=K3NP-PB2C-FLK6&select=5