Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 35 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON .
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal
MY4ZN-Y98 AC100/110 Name: Basic Unit (temperature control) *1 OMRON .
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2 .
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, 2 *3; Event inputs, 2 .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485 OMRON .
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel .
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method OMRON MY4ZN-Y98 AC100/110.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. Measuring range: 20±1mm.
Spot diameter: 40µm dia.
Static resolution: 0.25µm.
To achieve a compact Sennsoor Head and high-resolution measurements,
the ZW Series uses a white light confocal principle to detect objects OMRON MY4ZN-Y98 AC100/110.
This principle is described below.
MY4ZN-Y98 AC100/110 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MY4ZN-Y98 AC100/110&select=5