Classification: Momentary operation.
Shape of Operation Unit: 40 dia.
Output: 1.
Operation Unit color: Black (-B).
Long Service Life with Built-in Z-series.
Basic Switch.
Using a Basic Switch enables direct switching of large-capacity loads.
Shock-absorbing construction of Operation Unit protects the Switch OMRON G7L-2A-P-CB DC6.
Drip-proof Pushbutton construction enables use in locations subject to,
splashing water and oil and scattering dust
G7L-2A-P-CB DC6
Pushbuttons are available in three shapes and six colors. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase) OMRON G7L-2A-P-CB DC6.
Output specifications: One relay output .
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control OMRON G7L-2A-P-CB DC6.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Contact type: Microload (125 VAC, 0.1 A; 30 VDC 0.1 A).
Operation: Momentary operation (Self-resetting).
Output: SPDT.
Lighting: Incandescent lamp, 14 VAC/VDC.
Operation Unit color symbol: Enter the desired color symbol for the Pushbutton
n @. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer .4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output G7L-2A-P-CB DC6.
Through the infrared port can be carried out from the frronnt of the communication G7L-2A-P-CB DC6.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
G7L-2A-P-CB DC6 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=G7L-2A-P-CB DC6&select=5