Operation/resetting system: Time-limit operation/self-resetting.
Time-limit contact: DPDT (for power switching).
Time ranges: 0.04 s to 3 h.
Supply voltage: 24, 100 to 120, 200 to 230, 240 VAC (50/60 Hz);
12, 24, 48, 125, 100 to 110 VDC.
Mounting: Surface/DIN-track mounting (with socket).
Miniature Timer Compatible with the MY Relay M22-FR-T1 Price.
Semi-multi power supply voltage.
Large transparent time setting knob facilitates time setting
M22-FR-T1
A flat-blade and Phillips screwdriver can also be used for time setting.
Pin configuration compatible with MY Power Relay.
LED indication for power and output statuses.
Conforms to EMC standards M22-FR-T1 Price.
Conforms to EN 61812-1 and approved by UL and CSA. Control output 1: Linear current output .
Auxiliary output: Two.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance M22-FR-T1 Price.
Handles More Applications.
The white PV display with a height of 15 . 2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature.
Controllers to each other. Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 10 A.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input condiitions: DC input is also possible from 80 to 370 VDC OMRON M22-FR-T1.
(Not compliant with EC Directives and other safety standards.) Operating modes: Power OFF Delay.
Supply voltage: 24 to 48 VAC/DC.
Control output: Contact output: SPDT.
H3DK-H: L Series (tiimee range: 1 OMRON M22-FR-T1. 0 to 120 s).
Set two time ranges with each Timer, from 0.1 to 12 seconds for,
the S Series and from 1.0 to 120 seconds for the L Series.
M22-FR-T1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=M22-FR-T1&select=5