Optical system: Diffuse reflective.
Beam shape: Line beam.
Sensing distance: 50±10mm.
Resolution: 1.5µm.
Stable, Easy & Affordable.
New Regular-reflective Sensor Head.
Designed for Optimal Wafer Measurement. Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit MSF4800B-30-0840 Price.
No. of control points: 2.
Control outputs 1 and 2: Current output: 2 points.
Control outputs 3 and 4: Transistor output: 2 points (sinking)
MSF4800B-30-0840
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, 2.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485 MSF4800B-30-0840 Price.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel .
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application MSF4800B-30-0840 Price.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design .
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. Appearance: Rectangular (M16-J).
Lighting: LED without Voltage Reduction Unit, 5 VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: 1.
Control output 1: Current output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 .5%),,
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs OMRON MSF4800B-30-0840.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannuaal, RUN/STOP, and alarms) and the PV or SV OMRON MSF4800B-30-0840.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
MSF4800B-30-0840 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MSF4800B-30-0840&select=5