Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2
P2CF-08
External connections: Screw terminals OMRON P2CF-08.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Contact output (time-limit SPDT) .
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Type: Reverse wiring.
Cable length L: 5.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Connection method: Pre-wired.
Cable length: 5 m OMRON P2CF-08.
Sensing distance: 50 ± 10 mm.
Model: PNP output.
A CMOS Laser Sensor That’s .
Optimum for Simple Measurements.
A resolution of 0.002 mm that’s suitable for simple measure ments.
Stable measurements for any type of workpiece.
Models available with four different distance specifications.
Long-distance model for up to 1,000 mm. Release key type: Special release key.
Indicator: Orange.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+3NC.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: -.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance perfformance .
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal P2CF-08.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsiion Village (sold separately) connected to the computer after,
No power connection can be set P2CF-08.
It can be easily set by CS-Thermo (sold separately).
P2CF-08 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=P2CF-08&select=5