Number of beams: 38.
Protective height: 785mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions H3Y-2 AC100-120 60M. Specifications: Inputs;
PNP (- common); 32 points.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector
H3Y-2 AC100-120 60M
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e H3Y-2 AC100-120 60M. g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H) . Type: Welding / wire type, M3 screw mounting.
Drive rod: needle shaped button type.
Terminal specification: welding.
Contact specifications: 1c.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment H3Y-2 AC100-120 60M.
No swing bars are also used for easy long stroke specifications (OT reference value: 1 . 4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Power supply voltage: DC.
Sensing method: Retro-reflective with MSR function.
Sensing distance: 10 m[100 mm](When using E39-R2).
Output configu ration: PNP.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models).
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2.5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC).
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available. Specifications: 16 Kwords without clock.Rated voltage: 200 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2300 r/min; 60 Hz, 2600 r/min.
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 41 Pa; 60 Hz, 45 Pa.
Noise: 50 Hz, 41 dB; 60 Hz, 44 dB.
Weight: Approx. 1150 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and concealss the hole-cut to,
simplify installation work OMRON H3Y-2 AC100-120 60M.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and VVennt Attachment OMRON H3Y-2 AC100-120 60M.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.
H3Y-2 AC100-120 60M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=H3Y-2 AC100-120 60M&select=5