Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work MKS3P-V-2 AC120.
Ideal for the thermal input devices of Temperature Controllers
MKS3P-V-2 AC120
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Type: power AC/DC24V with MKS3P-V-2 AC120.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode .
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type MKS3P-V-2 AC120.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved .
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Type: Welding / wire type, with right column.
Driving rod: R type swing lever type.
Terminal specification: welding.
Contact specifications: 11c OMRON MKS3P-V-2 AC120.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used fforr easy long stroke specifications (OT reference value: 1 OMRON MKS3P-V-2 AC120. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free.
MKS3P-V-2 AC120 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MKS3P-V-2 AC120&select=5