Ratings: 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable*.
Actuator: Pin plunger.
Cable length : 3m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection OMRON A22L-TA-24A-20M.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
A22L-TA-24A-20M
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables OMRON A22L-TA-24A-20M.
Multiple mounting possible with Switches with Plungers .
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Appearance: M12.
Sensing distance: 2 mm.
Connection method: Pre-wired Models (2 m) OMRON A22L-TA-24A-20M.
Cable specifications: PVC (oil-resistant).
Operation mode : NC .
Pin arrangement: -- .
Applicable connector code: --.
Model: PNP output.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. E32-D25X type: standard type; standard,
Specialty: flat shape (small),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsConfiguration: Covered Power Supplies.
Input voltage: 100 to 120 VAC 200 to 240 VAC (Switchable).
Power ratings: 300 W.
Output voltage: 5 V.
Output current: 60 A.
Built-in fan: Yes.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safetty standards: UL 5088/60950-1, cUL CSA C22 A22L-TA-24A-20M.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The inpuut voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply A22L-TA-24A-20M. ).
A22L-TA-24A-20M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22L-TA-24A-20M&select=5