Sensing method: Diffuse-reflective Sensors.
Appearance: Vertical.
Connection method: Pre-wired.
Sensing distance: 200 mm.
Functions: Timer Self Diagnosis Turbo.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped OMRON A3PA-5703-05E.
Cable diameter: 6.0 mm dia.
No. of cable cores: 3.
Cable core cross sectional area: 0
A3PA-5703-05E5 mm.
Cable length: 1 m.
DC.
Minimum order: 10.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating OMRON A3PA-5703-05E.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime .
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202 OMRON A3PA-5703-05E. Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability .
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and input circuits are isolated for safety and reliability.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer or,
the load.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection. Safety outputs *3: Instantaneous, 3(Semiconductor);
OFF-delayed*2, 2 (Semiconductor).
Auxiliary outputs *4: 2(Semiconductor).
Logical AND connection: Inputs, 1(Semiconductor); Outputs, 1(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control syystem setup .
Sollid-state outputs (excluding Expansion Units) A3PA-5703-05E.
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unnitt joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set A3PA-5703-05E.
-Two logical AND connection inputs.
A3PA-5703-05E Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3PA-5703-05E&select=5