Control output 1: Linear current output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation OMRON A3PJ-90DG1-24EK.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15
A3PJ-90DG1-24EK2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other OMRON A3PJ-90DG1-24EK. Number of connections to the image machine: 2 .
Image storage function: up to 35 images can be stored.
Memory card slot: 1.
Monitor interface: 1 channels.
Ethernet: does not support.
Parallel I/O:13 inputs and 22 outputs. Unit type: CS-series Special I/O Units.
Product name: Analog Input Units.
Specifications: I/O points, 8 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max OMRON A3PJ-90DG1-24EK.
(Settable to 1 ms/point).
Externa connection, Removable terminal block.
Current consumption: 5V, 0.12A; 26V, 0.09A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Output: DPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be useed for both standard loads and microloads A3PJ-90DG1-24EK.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Amplifier Units.
Power supply/Output: DC/(PNP).
Timer function: --.
Self-diagnostic output: --.
Separate Amplifier Sennsoor with A3PJ-90DG1-24EK.
Sensitivity Adjustment.
Compact design with smaller Sensor Head.
Heat-resistance model available for application between.
-10 and 200°C.
A3PJ-90DG1-24EK Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3PJ-90DG1-24EK&select=5