Absolute diameter 65.
High resolution absolute type for detecting instrument and precision positioning.
To achieve a resolution of 12 bits (maximum 4096) of high resolution.
Response frequency is the high speed response of 40kHz
Output with gray code and BCD code.
The shape is smaller than the old one OMRON CQM1-TC303.
Power supply voltage: DC5 ~ 12V.
Output form: BCD.
Output code: Gray 2. Appearance: Rectangular (M16-T)
CQM1-TC303
Lighting: Incandescent lamp, 5 VAC/VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch OMRON CQM1-TC303. Timer input: PNP/NPN universal DC voltage input(4 . 5 to 30 VDC).
Display: 7-segment LCD with backlight.
Time range: 999999.9h ←→ 3999d23.9h(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V) OMRON CQM1-TC303.
Shell color: black.
Control output: current output .
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Receptacle box: G 1/2 Conduit.
Indicator: With neon lamp indicator (AC).
Actuator: Roller lever *1, Standard.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) .
Wide sttandard operating temperature range:
-40°C to +100°C (standard type) CQM1-TC303.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavaailable for complex operations CQM1-TC303.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
CQM1-TC303 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=CQM1-TC303&select=5