Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @ OMRON D4D-6532R.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock
D4D-6532R
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices OMRON D4D-6532R.
(4-, 5-, and 6-contact models are available) .
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames OMRON D4D-6532R.
The plastic material makes the Slide Key suitable,
for lightweight doors . Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Analog (current/voltage).
Alarm output: 3.
Control output: Current output.
Functions: Heater burnout, --; Mounting option units, Yes.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Ratings: 1 A at 125 VAC.
LED indicator: Without indicator.
Actuator: Sealed crossroller plunger.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New cennter roller leever models that enable ganged mounting D4D-6532R.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(sstaandard indicator is lit when Switch is not operating) D4D-6532R.
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.)
D4D-6532R Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=D4D-6532R&select=5