Output: DPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28 OMRON . 5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
A22RW-2AA-6A-01
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Control output: relay output.
Auxiliary output: -.
Heating wire break, SSR fault detection function: - OMRON .
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit) .
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body OMRON .
The terminal platform can be easily replaced, and the maintenance performance is improved .
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 2 m.
DC.
Minimum order: 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 reequirements and ensure a,
94V-0 fire retardant rating OMRON A22RW-2AA-6A-01.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnnector Assembly: Crimping, soldering, and screw-on OMRON A22RW-2AA-6A-01.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
A22RW-2AA-6A-01 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22RW-2AA-6A-01&select=5