Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 100/110 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia OMRON . Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch
A3SA-90B1-24EY
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; M12 connector OMRON .
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches .
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability OMRON .
Can be used with both standard loads and microloads .
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 80.
Protective height: 1,630mm.
Model: NPN.
Easy-to-use Safety Sensor Ideal for.
Simple On/Off Detection Applications.
Provides simple safety functions - saving TCO.
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms. Appearance: Round/Projection type LED voltage-reduction lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing thhe Switch Unit OMRON A3SA-90B1-24EY.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounteed using either open-type (fork-type) or closed-type OMRON A3SA-90B1-24EY.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
A3SA-90B1-24EY Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3SA-90B1-24EY&select=5