Power supply voltage: 5 to 12 VDC.
Output configuration: Open-collector output (NPN output).
Output phases: Phases A .
Resolution (pulses/rotation): 10, 20, 60, 100, 200, 300, 360, 500.
Compact Encoder with External.
Diameter of 25 mm.
Incremental model.
External diameter of 25 mm.
Resolution of up to 500 ppr OMRON A165-TYA-2S. Size: 48 x 48mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 3 points (common universal)
A165-TYA-2S
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485 OMRON A165-TYA-2S.
Event input: 1 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility .
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications OMRON A165-TYA-2S.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Time specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indiccated from the start of operation A165-TYA-2S.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions A165-TYA-2S. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.