Specification: Four contacts, vertical mounting, with rubber seal.
3-position Enabling Switch for Safer.
Robot Operation.
Clicking feel.
Conforms to U.S. standards (ANSI/RIA R15.06-1999) for.
3-position switches.
Can be mounted in two directions. CPU Unit: CP1L-M CPU Units with 60 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sourcing);
Inputs, 36; Output, 24
A22L-TR-T1-20A
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet OMRON A22L-TR-T1-20A.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port .
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Type: plug - in.
Size: 48 x 96mm.
Control output: relay output.
Auxiliary output: 2 points.
Communication: -.
Heater disconnection: - OMRON A22L-TR-T1-20A.
Event input: -.
Power supply voltage: AC/DC24V.
Using large font PV display (white), improve visibility .
Selection, setting and operation more simple and more group of input / output,
Functional performance is stronger, the function is more perfect and more extensive range of applications.
E5EC-800 white LCD-PV display height is about 18mm,
The E5AC-800 white LCD-PV display height is about 25mm improved visibility.
The main body is short, the thickness is only 60mm.
50ms high speed sampling period.
A new type of proportional control allows you to control the valve. Applicable model (typical example): MY2.
New Screwless Terminal Sockets Added.
for MY and G2R Relays.
Simplified wiring without tightening screws.
Two wires can be independently wired for each terminal.
Coil terminals and contact terminals are completely separated,
in an organized wiring layout.
Release Levers and Nameplates are available (sold separately). Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer .4.3 CX-Thermo)) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output A22L-TR-T1-20A.
Through the infrared port can be carried out from the frronnt of the communication A22L-TR-T1-20A.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
A22L-TR-T1-20A Operation manual/Instructions/Model selection sample download link: