Supply voltage: 24 to 230 VAC (50/60Hz)/24 to 48 VDC.
Control output: Contact output: SPDT (time-limit output SPDT).
Input type: No-input available.
Operating mode(see note): Eight multi-modes: Single mode: A.
Model: Screw terminal type.
Eight operating modes (H3DS-M) and four operating modes,
(H3DS-S) cover a wide range of applications A165S-T3MA.
A wide time setting range of 0.10 s to 120 h.
Two LEDs indicate power and relay status respectively
A165S-T3MA Number of beams: 70.
Protective height: 1745mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors A165S-T3MA.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions . Sensing method: Through-beam.
Sensing distance: 500 mm.
Output configuration: NPN open collector NO (normally open).
Compact, Through-beam, Ultrasonic.
Sensor.
Provides stable detection of transparent films, transparent.
bottles, PET bottles, and other similar workpieces A165S-T3MA.
Compact design with built-in amplifier allows easy mounting.
on small conveyor lines .
Detects as far as 500 mm away.
Equipped with stability indicator. General-purpose Encoder with.
External Diameter of 40 mm.
Incremental model.
External diameter of 40 mm.
Resolution of up to 2,000 ppr. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savinngs in cost and spacee compared,
with previous systems OMRON A165S-T3MA.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems OMRON A165S-T3MA.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
A165S-T3MA Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A165S-T3MA&select=5