Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: No.
Control output: Transistor (opencollector) A22RL-TG-24A-01A.
Operating mode: Down counting.
Max.counting speed: 5 kcps (see note 1
A22RL-TG-24A-01A).
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter A22RL-TG-24A-01A.
Power supply freely selectable within a range of 100 to 240 VAC .
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC A22RL-TG-24A-01A.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) .
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Appearance: Key-type Selector Switch A22K.
Number of notches: 2 nnotches .
Reset method: Auutomatic OMRON A22RL-TG-24A-01A.
Output: SPST-NC.
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Socket Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ringg tto install in 25-dia OMRON A22RL-TG-24A-01A. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round type) crimp terminals.
IP65 oil resistance.
A22RL-TG-24A-01A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22RL-TG-24A-01A&select=5