Isolation: Photocoupler.
Zero cross function: --.
Indicator: Yes.
Rated output load: 3 A at 4 to 48 VDC (See note 2.).
Rated input voltage: 5 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”) C200HW-NC113.
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input
C200HW-NC113
(model numbers with “N” before the suffix). Product name: CJ1M CPU Units; built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
640 points/20 Units(1 Expansion Racks max C200HW-NC113. ) ; Program capacity,
20K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0 . 1 μs;
Built-in I/O , 10 inputs and6 outputs,
2 counter inputs, 2 pulse outputs.
Current consumption: 5v, 0.64A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. CPU Unit: CP1L-M CPU Units with 40 Points C200HW-NC113.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sinking);
Inputs, 24; Output, 16 .
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Cable length L: A, 1.0 m; B, 0.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manuual, RUN/STOP, alarm), interactive display PV/SV OMRON C200HW-NC113.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation OMRON C200HW-NC113.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
C200HW-NC113 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=C200HW-NC113&select=5