Voltage input: DC0~10V, DC0~5V.
Current input: DC4~20mA.
Number of channels: 2 channel analog.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
High precision analog output module with 12 bit resolution.
Voltage output and current output of 2 channels can be carried out MITSUBISHI .
Can be specified for each channel voltage or current output. Cable length: 5m
A70BDE-J71QLR23
For MR-J2S-700A (4) /CP/CL or less.
Encoder for HC-KFS; HC-MFS; 3000r/min HC-UFS servo motor.
-H products have a long flex life. QnA/ACPU bus connection.
1 joint.
Applicable model: A956WGOT. Enter points: 64 points MITSUBISHI .
Input voltage: DC7V above.
Input response time: 16ms.
16 pin connector .
Output points: 64 points.
Output response time: 16ms.
Output type: transistor output.
32 pin connector.
Dynamic input and output.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI .
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signaal transmission device, brake ssignal and fan fault signal MITSUBISHI A70BDE-J71QLR23.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee ssystem controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points MITSUBISHI A70BDE-J71QLR23.
A70BDE-J71QLR23 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A70BDE-J71QLR23&select=5