Power: 75kw.
Voltage: 400V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor.
Can also be connected without built-in brake transistor inverter.
Three types of discharge resistors are available MITSUBISHI .
Please select according to the required braking torque. Max input / output points: 40 points.
Power supply voltage: 12-24VDC
GT25-05UCOV
Input points: 24 points.
Output points: 16 points.
Output type: Transistor (source).
Power consumption (W): 18.
Weight (kg):0.65.
Size (WxHxD) mm:130x90x75.
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc MITSUBISHI . .
CPU, power supply, input and output integration.
Display module or function expansion board can be less installed.
In addition, you can also reduce the input output or special module.
Built in 8000 step EPROM memory.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards MITSUBISHI .
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board .
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control. Input points: 16 points.
Voltage: DC12/24V.
Current: 4/10mA.
Response time: 10ms.
8 points / a common end.
Cathode common.
20 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The coontents of the component immage register are changed with the change of the execution of the program MITSUBISHI GT25-05UCOV.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling MITSUBISHI GT25-05UCOV.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.