Input and output points: 14 points.
Power supply: DC24V.
Input points: 8 points.
Output points: 6 points.
Output form: relay output.
Power consumption: 6.5W.
Weight: 0.22KG.
Outline dimension: 60x90x49mm.
Built in CPU, power supply, input and output.
Keep FX1S compact body, while adding more features MITSUBISHI MR-H100AN.
Special adaptor and function expansion board can be installed and used FX3 series.
High speed operation
MR-H100AN
Basic instructions: 0.21 s/ instruction
Application instruction: 0.5 s/ instruction
Large capacity memory.
Built in program memory 4000 steps.
No battery.
Auxiliary relay: 1536 points.
Timer: 138 points.
Counter: 67.
Data register: 3000 MITSUBISHI MR-H100AN.
A new application model.
FX3SA is a basic model on the basis of the basic performance of the FX1S increased the expansion of the new models .
FX3SA is suitable for all kinds of fields, such as analog quantity, Ethernet, MODBUS function, small scale equipment and so on.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and the communication function and so on MITSUBISHI MR-H100AN. Total points: 10 points.
Input points: 6 points .
Output points: 4 points.
Voltage: AC220V.
Output type: relay.
Outline dimension: 60*75*90.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment.SRAM+E2PROM memory card.
RAM capacity: 128KB.
E2PROM capacity: 128KB. 8 slots.
To install the power supply.
For Q4AR power duplex.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Cenntralized outpput mode MR-H100AN.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation MR-H100AN.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
MR-H100AN Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-H100AN&select=5