LK Automation Limited
Home >> Price >> MITSUBISHI >> MR-J4-DU30KA MITSUBISHI MR-J4-DU30KA
Brand sort

MR-J4-DU30KA MITSUBISHI MR-J4-DU30KA

Country: JAPAN
Name: Servo driver
Model: MR-J4-DU30KA
Price: 0
MITSUBISHI MR-J4-DU30KA
Input type: DC input, positive public end / negative public end.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 1 wire.
40 pin connector type (FCN connector type).
Through the 40 pin connector type (FCN connector type) can be connected to a variety of devices MITSUBISHI MR-J4-DU30KA.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program MR-J4-DU30KA
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation MITSUBISHI MR-J4-DU30KA. Input type: DC input, positive common end.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type MITSUBISHI MR-J4-DU30KA.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting .
3 wire sensor input. Type: 18 point terminal.
Input / output form: analog voltage and current input.
Number of stations: 1 stops.
Number of channels: 4 channels.
The conversion speed of the analog input module can be selected from 100 mu s/ channel, 400 mu s/ channel and 1 mu s/ channel.
The conversion speed of the analog output module is 100 mu s/ channel.
By combining the analog input module and the expansion module, the switching time can be controlled more precisely. (trigger conversion function)
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 8A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
20 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoidd valve can be knnown,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 outtput, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MR-J4-DU30KA MR-J4-DU30KA.
MR-J4-DU30KA Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=MR-J4-DU30KA&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Servo driver
MR-J4-DU55KB4-RJ
MITSUBISHI Servo driver MR-J4-DU55KB4-RJ
Drive unit. MITSUBISHI universal AC serv
MITSUBISHI
Servo driver
MR-J4-20A-RJ
MITSUBISHI Servo driver MR-J4-20A-RJ
"1 axis servo amplifier. MITSUBISHI gene
MITSUBISHI
Servo driver
MR-J4-700B4-RJ
MITSUBISHI Servo driver MR-J4-700B4-RJ
1 axis servo amplifier. MITSUBISHI gener
MITSUBISHI
Servo driver
MR-J4-11KA4-RJ
MITSUBISHI Servo driver MR-J4-11KA4-RJ
1 axis servo amplifier. MITSUBISHI gener