The connector is converted to a spring clip terminal row.Power: 55kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity MITSUBISHI NZ2AW1C2D2.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor
NZ2AW1C2D2)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Servo motor series: medium inertia, medium power MITSUBISHI NZ2AW1C2D2.
Rated output: 5.0kw.
Rated speed: 2000r/min .
Electromagnetic brake: No.
Shaft end specification: Standard (straight axis).
Characteristics: medium inertia has two types of low speed and high speed, suitable for different applications.
IP level: IP67.
Application example:
1, material handling system.
2, industrial robots.
3, X-Y working table.
The protection level of the HF-SP/HF-JP series servo motor is IP67 (except the shaft part) MITSUBISHI NZ2AW1C2D2.
Motor capacity selection soft (MRZJW3-MOTSZ111E)
Friendly interface design, only in the mechanical description window input constant and operation mode can choose the best servo amplifier,
The servo motor and the regenerative braking options, but also in the selection window in the selection of linear servo motor and direct drive motor.
Characteristic
(1) 10 typical mechanical transmission structure can be used to choose
(2) user defined operating modes (location and speed control)
(3) in the selection process, the feed speed and torque can be displayed in a graphical format.
(4) the calculation process can be displayed
Can easily calculate the power of the servo motor free software!Memory card interface, serial interface.
On-line debugging is the process that will through the simulation debugging to furtherr carry on the on-line unification to adjust NZ2AW1C2D2.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on stepp bby step NZ2AW1C2D2.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.
NZ2AW1C2D2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=NZ2AW1C2D2&select=5