Positioning: 3 axis, built-in counter function, open collector output type.
Control unit: pulse.
Number of location data: 1/ axis.
Maximum output pulse: 100Kpps.
Counter: 3 channels.
100Kpps.
Counter input signal: DV5~24V.
40 pin connector.
Positioning control using encoder feedback, especially suitable for conveying system and processing machinery, etc HC-MFS053BK. .
In the 1 single module, the 3 axis positioning function and the 3 channel counter function are integrated
HC-MFS053BK
Positioning module, high-speed counter module combined as a whole,
Can effectively use the board slot and save space. Input and output points: 30 points.
Power supply: DC24V HC-MFS053BK.
Input points: 16 points.
Output points: 14 points.
Output form: transistor output (drain) .
Power consumption: 8.5W.
Weight: 0.35KG.
Outline dimension: 100x90x49mm.
Built in CPU, power supply, input and output.
Keep FX1S compact body, while adding more features.
Special adaptor and function expansion board can be installed and used FX3 series.
High speed operation.
Basic instructions: 0 HC-MFS053BK. 21 s/ instruction
Application instruction: 0.5 s/ instruction
Large capacity memory .
Built in program memory 4000 steps.
No battery.
Auxiliary relay: 1536 points.
Timer: 138 points.
Counter: 67.
Data register: 3000.
A new application model.
FX3SA is a basic model on the basis of the basic performance of the FX1S increased the expansion of the new models.
FX3SA is suitable for all kinds of fields, such as analog quantity, Ethernet, MODBUS function, small scale equipment and so on.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and the communication function and so on. Power: 22kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reacch 300 degrees C or higher, it is necessary to take protective measures and cooling MITSUBISHI HC-MFS053BK.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between thhe short circuit chip, in addition to connecting the DC reactor MITSUBISHI HC-MFS053BK.
The installation of thermal relay, to avoid overheating and burn the braking resistor.
HC-MFS053BK Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HC-MFS053BK&select=5