Sale LD40PD01 MITSUBISHI LD40PD01

Country: JAPAN
Name: Multi function high speed I/O control module
Model: LD40PD01
Price: 0
MITSUBISHI LD40PD01
Enter 16 points or 16 points.
Directly connected to the input and output terminals of PLC;
Can play a role in replacing the terminal row;
Can also be far away from the PLC of the site when the input and output devices;
Use as relay;
In order to reduce the time of the input and output connection. CC-Link IE field network CC-Link bridge module LD40PD01.
Can support Ver.1 CC-Link remote I/O station and remote device station connected to the IE CC-Link field network LD40PD01
CC-Link parameters can be set by a simple switch operation.
According to the original station number order, will be allocated to the bridge module of link equipment as CC-Link remote station equipment distribution link LD40PD01.
The IE CC-Link field network and the CC-Link loop transmission are independent of each other .
The function module of MELSOFT Library (FB), the cache access bridge module,
To confirm and diagnose the running state of CC-Link. Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 100 K step.
Processing speed: 0 LD40PD01. 0095 s.
Program memory capacity: 400 KB.
Support USB and RS232.
Support installed memory card .
Providing high speed communication between multiple CPU.
High speed and high precision data processing.
The processing speed of the real number (floating point) arithmetic has been greatly improved,
Addition instruction reached 0.014 mu s,
Therefore, it can support the request of high-speed, high-precision processing data processing.
In addition, the new addition of double precision floating point arithmetic instructions,
Simplify the programming, reduces the computational error when executing complex formula.
Shorten the fixed scan interrupt time, high precision device.
The minimum interval of the fixed period interrupt program is reduced to 100 s.
The high speed signal can be accurately obtained, which makes the contribution to the higher precision of the device.5 slots.
No need to install power.
For QnA/A series.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Cenntralized output mode .

There exist input / output hysteresis phenomena, i MITSUBISHI LD40PD01.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation MITSUBISHI LD40PD01.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
LD40PD01 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=LD40PD01&select=5