Actuator: Roller lever: R38.
Item: Basic.
Connector shape: Threaded (M12).
Built-in switch type: General-purpose.
Voltage: DC.
Wiring locations: NO only 2 core.
Connector pin No: NO 1 4 .
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches
3G3JX-A2004
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting OMRON 3G3JX-A2004.
Approved standards: EN/IEC, UL, cUL, and CCC .
Contact your OMRON representative for information on approved models. Classification: Standard.
Contact gap: G (0.5 mm).
Actuator: Leaf spring.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types OMRON 3G3JX-A2004.
A series of standard models for micro loads is available.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common termiinal is provided for,
each connector 3G3JX-A2004.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswiitch and with tool software 3G3JX-A2004.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
3G3JX-A2004 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=3G3JX-A2004&select=5