Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
960 points (2 Racks);
Program capacity, 10 Ksteps;
Data Memory, 64 Kwords(DM: 32 Kwords,
EM: 32 Kwords×1 bank);
LD execution time, 0.04 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0 OMRON 3G3RV-PFI3060-SE. 78A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables
3G3RV-PFI3060-SE Appearance: Round/Half-guard type LED lighting,
(without Voltage Reduction Unit) A22L-H.
Output: SPST-NC.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Operation: Momentary operation (self-resetting) OMRON 3G3RV-PFI3060-SE.
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue) .
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia OMRON 3G3RV-PFI3060-SE. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type .
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / maanual, RUN/STOP, alarm), interactive display PV/SV 3G3RV-PFI3060-SE.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation 3G3RV-PFI3060-SE.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
3G3RV-PFI3060-SE Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=3G3RV-PFI3060-SE&select=5