Specifications: 16 Kwords with clock.Includes text book, cassette tape, and input switch board.Pressure range: 0 to 200 Pa.
Digital output: NPN open collector.
Linear output: 4 to 20 mA.
Micropressure Sensor with.
Easy-to-Read Digital Display.
Repeat accuracy of ±1% FS (setting resolution: 0.01 kPa),
high-precision pressure control available OMRON 42669-0200 PCA-MS43-12IN-RX-MI.
Compact design (31 × 30 × 30 mm) saves mounting space
42669-0200 PCA-MS43-12IN-RX-MI
Easy-to-read red LED indicator.
Analog current output models available (E8Y-A@Y).
Pressure port Rc (PT) 1/8 models available (-R).
EN and UL approved. Number of beams: 12 OMRON 42669-0200 PCA-MS43-12IN-RX-MI.
Protective height: 360mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance .
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module OMRON 42669-0200 PCA-MS43-12IN-RX-MI.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B .
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Standard certification: No.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC12V.
Insulation mode: three end two-way photoelectric switch.
Zero crossing trigger function.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the startt of operation 42669-0200 PCA-MS43-12IN-RX-MI.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions 42669-0200 PCA-MS43-12IN-RX-MI. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
42669-0200 PCA-MS43-12IN-RX-MI Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=42669-0200 PCA-MS43-12IN-RX-MI&select=5