No. of cable cores: 5.
Cable core cross sectional area: 0.3 mm.
Cable length: 10 m.
DC.
Minimum order: 5.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime OMRON 44507-0024 MA-1DPC4.
Connectors with Cables and Connector Assemblies are available
44507-0024 MA-1DPC4
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202 OMRON 44507-0024 MA-1DPC4. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V) .
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function OMRON 44507-0024 MA-1DPC4.
Event input points: -.
Transfer output: -.
Communication: RS-232C .
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Cable: PVC.
Cable core number (core): 4.
Cable outlet directtion: L type .
Cable lenngth L:5m 44507-0024 MA-1DPC4.
The province, province hours maintenance, use waterproof connector environment and strong tolerance of FA.
Conform to IP67. FA small special connector flame retardant 94V-0.
The connector wiring system, convenient eequuipment maintenance, reduce equipment downtime 44507-0024 MA-1DPC4.
IEC61076-2-101 (IEC60947-5-2).
For LED products, can clearly confirm the status of the sensor action.
44507-0024 MA-1DPC4 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=44507-0024 MA-1DPC4&select=5