Model: Shielded, M8.
Sensing distance: 1.5 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NC.
Proximity Sensor with Resin Case,
with Superb Water Resistance.
IP68 protection.
Mutual interference prevention with models with different,
frequencies is also available. CV500-BS CPU Bus Unit BASIC Unit CV500-BSC61 OMRON 44538-6230 T4012-031F2M-SC1.
RS-232C: 1 port.
GP-IB: 1 port.
(w/EEPROM).Appearance: ADR shell
44538-6230 T4012-031F2M-SC1
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3 OMRON 44538-6230 T4012-031F2M-SC1. 5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0 . 25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not OMRON 44538-6230 T4012-031F2M-SC1.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times .
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced technology of fuzzy inference to make the protection and coordination of digital DCR.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any time.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm. Miniiature Timer with Multiple Time Ranges,
and Multiple Operating Modes 44538-6230 T4012-031F2M-SC1.
UL listed when used with a Push-In Plus Terminal Block Socket.
Conforms to CSA, CE Marking, LR, and CCC.
Black design with power supply terminals on top and contact output,
teerminals on bottom 44538-6230 T4012-031F2M-SC1.
Standard multiple operating modes and multiple time ranges.
Pin configuration compatible with MY Power Relay.
Minimizes stock.
44538-6230 T4012-031F2M-SC1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=44538-6230 T4012-031F2M-SC1&select=5