OMRON 70062-1046 SRU23
Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 2 notches.
Resetting method: Automatic.
Output: SPST-NC.
Operating voltage: 200 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia OMRON 70062-1046 SRU23. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature 70062-1046 SRU23
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models) OMRON 70062-1046 SRU23.
IP65 (lighted models). Cable /G79-Y_C with loose wire connecting terminal .
L size: 5000mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Type: 1C contact type.
Shape: round.
Terminal shape: solder terminal.
Action: instantaneous.
Display mode: do not display.
Operation Department color: blue OMRON 70062-1046 SRU23.
Large capacity compact type push button switch.
Can also be used as a power switch with a large capacity cut .
Can be switched from micro load (minimum applicable load 1mA DC5V) to large capacity load. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation 70062-1046 SRU23.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions 70062-1046 SRU23. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.