LK Automation Limited
Home >> Price >> MITSUBISHI >> AJ65SBTB1-16T1 MITSUBISHI AJ65SBTB1-16T1
Brand sort

AJ65SBTB1-16T1 MITSUBISHI AJ65SBTB1-16T1

Country: JAPAN
Name: Transistor output module
Market price: U.S.$ 0
(The following are the market open price not sales price!)
MITSUBISHI AJ65SBTB1-16T1
RS-232 1 channel.
RS-422/485 1 channel.
Transfer speed: 2 channels.
A total of 115.2kbps.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive AJ65SBTB1-16T1
Semiconductor circuit with memory function.
System program memory and user memory.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation MITSUBISHI AJ65SBTB1-16T1.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. 5 slots.
Can be installed in the power supply unit for A series units installed QnA/.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program MITSUBISHI AJ65SBTB1-16T1.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should bee determined accordding to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point AJ65SBTB1-16T1.
Taking into account the future adjustment and expansion,
In general should be estimaateed on the total number of points plus the amount of spare 20%~30% AJ65SBTB1-16T1.
The following describes the centralized control system I/O points of the estimate.
AJ65SBTB1-16T1 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=AJ65SBTB1-16T1&select=5