PLC station distance: 500M.
Cable type: coaxial cable.
The function of the MELSECNET interface module is to connect the main CPU PLC to the MELSECNET data communication system.
As long as the switch on the component to set,
Can determine the CPU PLC is as the main station or in situ station.
There are two modules available for selection: one is the connection of the optical cable network and the network of the coaxial cable
AJ71VP21
For a ANSCPU, up to only a piece of interface components can be inserted, A2ASCPU can be inserted 2.
The popularization and application of PLC programming has been developed rapidly in our country,
It has been widely used in all kinds of mechanical equipment and production process of electrical control devices,
All walks of life have emerged a large number of application of PLC transformation of the results of the equipment MITSUBISHI AJ71VP21.
Understand the working principle of PLC, have the ability to design, debug and maintain the PLC control system,
Has become the basic requirements of modern industry for electrical technicians and engineering students MITSUBISHI AJ71VP21.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations .
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram. Its characteristics are basically consistent with the ladder diagram language. MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 355kw.
SLD converter rated current: 866A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
To maximize the performance of the motor.
Advanced auto tuning function.
The newly developed PM motor auto tuning feature can be used to operate other manufacturers of PM motors (Yong Ci synchronous motors) in the sensorless state.
Not only can drive MITSUBISHI induction motor and PM motor, but aalso can drivve other manufacturers of induction motor and PM motor AJ71VP21.
This means that you can reduce the cost of inventory and supplies.
If the PM motor is produced by a IPM motor or other company using MM-CF, the starting torque is limited to 50%,
EEveen after tuning is not simple to use and positioning control of zero speed torque) induction motor and permanent magnet motor can be combined freely AJ71VP21.
AJ71VP21 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=AJ71VP21&select=5