MITSUBISHI FX-16EX-C
Analog input channel number: 4CH.
Available thermocouple: -.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range MITSUBISHI FX-16EX-C.
Sensor input when the action: according to the scale of the processing FX-16EX-C
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: there.
External wiring connection mode: 18 point screw terminal MITSUBISHI FX-16EX-C.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control .
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control MITSUBISHI FX-16EX-C. Can be combined with the function of the following two points .
Heating function between modules.
Peak current suppression function between modules.
By cooperating with the time of arrival of a number of loops, the average temperature is controlled.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomenon of thermal expansion. Can be divided into 16 groups, with its heating up to the time,
Reduce the overall system in heating up the waste of energy.
Peak current suppression function between modules
By the time staggered output transistor, suppressing peak current.
The power supply capacity of the equipment can be reduced by setting a larger channel and a smaller channel of the heater in the same set.
Can be divided into 5 groups. 10BASE2.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal.
So the standard telecommunication number, the conversion between the number of operations to use a variety of computing.
This requires the resolution of the analog unit and the standard electrical signal.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation.
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simplified.
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Need to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers. Poor visibility and operability.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the currennt input combiination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order FX-16EX-C.
So, sometimes also known as the order control.
And seqqueential control is divided into manual, semi-automatic or automatic FX-16EX-C.
And the control principle is decentralized, centralized and hybrid control three.
FX-16EX-C Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FX-16EX-C&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Terminal module
FX-16EYS-TB
MITSUBISHI Terminal module FX-16EYS-TB
Output points: 16 points. SCR output typ
MITSUBISHI
Output expansion module
FX-16EYS-ES-TB/UL
MITSUBISHI Output expansion module FX-16EYS-ES-TB/UL
Output: 16 points. Function: idirection
MITSUBISHI
Output expansion module
FX-16EYT-ESS-TB/UL
MITSUBISHI Output expansion module FX-16EYT-ESS-TB/UL
Output: 16 points. Function: transistor
MITSUBISHI
Terminal module
FX-16E-TB
MITSUBISHI Terminal module FX-16E-TB
Enter 16 points or 16 points. Directly c