LK Automation Limited
Home >> Price >> MITSUBISHI >> FX0S-20MR-D MITSUBISHI FX0S-20MR-D
Brand sort

FX0S-20MR-D MITSUBISHI FX0S-20MR-D

No PHOTO
Country: JAPAN
Name:
Model: FX0S-20MR-D
Market price: U.S.$ 0
(The following are the market open price not sales price!)
MITSUBISHI FX0S-20MR-D
Three-phase 3 wire type.
Measuring circuit number: 1 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information FX0S-20MR-D
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device MITSUBISHI FX0S-20MR-D.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment .
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products MITSUBISHI FX0S-20MR-D.
For example, a module can be used to measure other loads from the control panel trunk .
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Coaxial data communication line function.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage cappacity: it is a measure of how much the user application can store the number of indicators FX0S-20MR-D.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words FX0S-20MR-D. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
FX0S-20MR-D Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FX0S-20MR-D&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
PLC
FX1S-20MR-D
MITSUBISHI PLC FX1S-20MR-D
Max input / output points: 20 points. Po
MITSUBISHI
PLC
FX1S-30MR-D
MITSUBISHI PLC FX1S-30MR-D
Max input / output points: 30 points. Po
MITSUBISHI
PLC
FX1N-60MR-D
MITSUBISHI PLC FX1N-60MR-D
Max input / output points: 60 points. Po
MITSUBISHI
PLC
FX2N-80MR-DS
MITSUBISHI PLC FX2N-80MR-DS
Max input / output points: 80 points. Po