Power: 7.5kw.
Voltage: 200V.
The surge voltage of the motor can be suppressed when the 400V motor is driven by a frequency converter.
Motor suitable for 5.5 to 37kW. "Enter points: 64 points.
Rated input voltage and frequency: DC24V.
Rated input current: TYP 4.0mA.
Response time: 0.1 ~ 70ms.
Common way: 32 point / public end MITSUBISHI HA-LFS601B.
Interrupt function: have.
External wiring connection: 40 pin connector two
HA-LFS601B
Easily connect input and output terminals with high density.
An input / output module with 16 points, 32 points, 64 points is provided.
According to the user system to select the most suitable models, help to save space and cost MITSUBISHI HA-LFS601B.
The terminal row is compatible with the Q series, and can be used directly by the terminal of the existing system .
Therefore, the wiring cost can be reduced when the system is updated.
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors MITSUBISHI HA-LFS601B.
The input and output number stamped on the top of the front display input and output module LED, can easily confirm the status of the ON/OFF .
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented.
The 64 point module can be 32 points as the unit, through the switch to switch to display the input and output number.
In addition, serial number tag in the front of the module, can be easily recognized. "Cable length: 20m.
For connection between FXCPU (MINI-DIN8 pin connector) and GOT.
Connection between FXCPU communication function extension board (MINI-DIN8 pin connector) and GOT.
Applicable models: GT10, GT21. RS-422 1 channel, RS-422/485 1 channel.
Transfer speed: 0.3-19.2kbps.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, iinverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state oof tthe machine movement,
Make maintenance work efficiency also greatly improved HA-LFS601B HA-LFS601B.
Q series PLC in the use of CC-Link function better,
And easier to use.
HA-LFS601B Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HA-LFS601B&select=5