Input points: 16 points.
Input voltage and current: 6mA DC24V.
Response time: 0/0.1/0.2/0.4/0.6/1ms.
16 point /1 a public side.
Common anode.
18 point terminal station.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings MITSUBISHI HC-UFS72B. And there is no need to select the cable, the straight line and the cross line can be used
HC-UFS72B
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location MITSUBISHI HC-UFS72B.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields MITSUBISHI HC-UFS72B.
Can also be used in combination with the CPU module to achieve appropriate control .
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights."MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 30kw.
SLD converter rated current: 77A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based onn the operatioon of the inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements HC-UFS72B.
The control of each machine can be done separately by the frequency converter, and the controol of the dispersion is also carried out HC-UFS72B.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "