Protective film for 5.7 inch screen.
Transparent, 5.
Applicable model: GT105. Motor series: low inertia, medium capacity.
Rated output power: 37.0kw.
Rated speed: 1000rpm.
With the brake: without.
Voltage: 400V level.
Shaft end: straight shaft.
The rotor of the servo motor is a permanent magnet, which is controlled by the U/V/W,
The rotor rotates under the action of the magnetic field, and the encoder feedback signal of the motor is given to the driver,
According to the feedback value and the target value, the driver adjusts the rotation angle of the rotor
GT05-MEM-2GC
Accuracy of the servo motor depends on the accuracy of the encoder (number of lines) MITSUBISHI . Input points: 32 points.
Input voltage and current: 7mA DC24V .
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 24 points.
Output voltage: DC24V.
OFF leakage current: 0.1mA.
Output response time: 12ms.
Output type: transistor output.
8 point /1 a public side.
With the surge absorber.
34 point terminal station.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control MITSUBISHI .
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these sstandard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal MITSUBISHI GT05-MEM-2GC.
So the standard telecommunication number, the conversiionn between the number of operations to use a variety of computing MITSUBISHI GT05-MEM-2GC.
This requires the resolution of the analog unit and the standard electrical signal.
GT05-MEM-2GC Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=GT05-MEM-2GC&select=5