Oil resistant cap for 8.4 inch screen.
Applicable model: GT16. Input and output points: 480 points.
Input / output data points: 480 points.
Program capacity: 8k.
Basic command processing speed (LD command) s:1.25.
RAM memory capacity: 32K, power supply.
Modular: PLC is the basic components of a separate module MITSUBISHI .
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage
HC-SF502
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load MITSUBISHI .
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage capacity: it is a measure of how much the user application can store the number of indicators MITSUBISHI .
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. Servo motor series: flat type, medium power.
Rated output: 0.75kw.
Rated speed: 2000r/min.
Electromagnetic brake: No.
Shaft end specification: Standard (straight axis).
Features: flat type of the model is very suitable for servo motor installation space is limited occasions.
IP level: IP65.
Application example:
1, industrial robots.
2, food processing machinery.
Abundant motor product line can optimize the performance of the machine.
Has a rich motor product line including a rotary servo motor, linear servo motor and direct drive motor. Function: RS-485 communication.
CPU module connected to the front of the expansion function of the substrate.
The front of the CPU module can be connected to 1 units at most. Enter 32 points.
5mA DC24V.
Response time: 0.3ms.
32 point 1 public.
Output 32 points.
DC12/24V.
Leakage current: 0.1mA OFF.
Response time: 1ms. 32 point 1 public.
Protection function.
Surge.
40 pin connector.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the currennt input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI HC-SF502.
So, sometimes also known as the order control.
And seqqueential control is divided into manual, semi-automatic or automatic MITSUBISHI HC-SF502.
And the control principle is decentralized, centralized and hybrid control three.
HC-SF502 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HC-SF502&select=5