I/O control method: refresh mode or direct mode.
User program storage capacity: 30K step.
I/O points: 1024 points.
Memory capacity: bytes 192K.
ANSCPU has been updated to ANSHCPU, and it has the following advantages.
16 bit dedicated microprocessor.
Large capacity battery backup memory RAM.
Extended I/O control capability MITSUBISHI .
Dedicated CC-Link instruction.
Capacity for extended comment storage.
PLC programming is a digital computing operation of the electronic system,
Designed for applications in industrial environments
MR-J2S-350A
It uses programmable memory,
An instruction used to perform logical operations, sequence control, timing, counting and arithmetic operations in its internal storage,
And through the digital, analog input and output, control of various types of machinery or production process MITSUBISHI .
Programmable controller and related equipment,
Should be easy to make the industrial control system to form a whole, easy to expand the principle design of its functions. Input: 4 channels.
Platinum resistance (Pt100; JPt100) MITSUBISHI .
No heater disconnection detection function.
Sampling period: 0.5s/4 channel .
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusiion molding machine,
The teemperature regulating module has the function of preventing overheating and preventing over cooling MITSUBISHI MR-J2S-350A.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrroll (heating and cooling) mode MITSUBISHI MR-J2S-350A.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
MR-J2S-350A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-J2S-350A&select=5